8. Attach the magnetic coupler (1) to the visor housing as shown in Figure 4-36
with three pan-head screws, star lock washers, and flat washers.
9. Insert the end of the cable from inside the visor housing through the hole in the
housing leg (2) as shown in Figure 4-36. Carefully pull the cable through the
hole.
NOTE
If necessary, use a small amount of silicone adhesive type I in this
area to ensure that the cable will be positioned properly during visor
housing installation. Ensure that the adhesive cures properly before
reinstalling the housing.
10.
11.
12.
WARNING
Exercise care when using the heat gun.
Using a gun-type electrical heater (Item 10, Appendix B), install a 1 piece of
shrinkable electrical insulation sleeving (Item 17, Appendix E) on the cable and
against the visor housing leg for strain relief.
NOTE
In some cases, you may have to install shrinkable electrical insulation
sleeving of a larger diameter over the 1 shrinkable electrical insula-
tion sleeving installed on the cable.
Using a gun-type electrical heater (Item 10, Appendix B), install the larger shrink-
able electrical insulation sleeving (Item 17, Appendix E) for the connector clamp
onto the cable.
Slide the large piece of tubing that you removed in Disassembly step 3 onto the
cable.
Figure 4-36. Magnetic Coupler and Cable