TM 1-8415-216-12&P
4-14. Installing/Replacing Additionally Authorized Items
a. Converting Cobra dual visor module.
INITIAL SETUP
Tools/Equipment
Knife, pocket (GGG-K-484)
Screwdriver, cross-tip (XST-100)
Screwdriver, cross-tip
(GGG-S-121 TY6CL1)
Screwdriver, flat-tip
(GGG-S-121 TY1CL5DEB)
Punch, center, solid
(GGG-P-831 TY2CLASZ5)
Pliers, diagonal cutting
(GGG-P-468 TY1CL1)
Gun-type electric heater (8031088)
Soldering gun (3439-00-618-6623)
Metal cutting hand saw (HS5)
Drill, electric (SP6039)
Spatula (GGG-C-746)
#43 tap drill (MS15444-42)
#4-40 bottom tap (GGG-T-70)
Materials/Parts
AH-1 sight (2251773-00)
Cobra dual visor module)
(1680-ALSE-201-1, -2, -3, or -4
Insulation sleeving (454158-5)
Tin alloy solder (QQ-S-571)
Isopropyl alcohol pad (MIL-P-36792)
Personnel Required
ALSE Specialist or Personnel with ASI of Q2/H2
(ALSE Qualified)
68X Armament/Electrical Systems Repairer
Disassembly
1. Referring to Figure 4-32, remove the housing on the connector plug (3) as
follows:
(a) Remove the pin that passes through the housing and the connector.
(b) Loosen the two screws that attach the connector housing clamp to the
cable and slide the connector housing from the connector body.
WARNING
Exercise care when using the soldering gun.
2. Using soldering gun (Item 12, Appendix B), unsolder the eight conductors
attached to the connector terminals.
CAUTION
Be careful not to cut the cable if you have to cut
the shrinkable electrical insulation sleeving away
from the connector.
3. Slide the larger strain relief shrinkable
electrical insulation sleeving from the
connector and the smaller strain relief
electrical insulation sleeving from the
leg (2) of the visor housing.
Figure 4-32. AH-1 Cobra Module
4-35