TM 1-5855-265-20
3-8
3-3. MOVING PNVS TURRET ASSEMBLY MANUALLY (cont)
NOTE
If brake release power supply assembly is not
connected, go to step 9 below.
8. Disconnect brake release power supply
assembly (4).
a. Set POWER switch (8) to OFF.
b. Disconnect cable (9) from brake release
power supply assembly (4) and AIA
connectors.
c. Stow cable (9) inside cover (10) of brake
release power supply assembly (4).
d. Close and latch cover (10).
e. Connect helicopter cable connectors to AIA
connectors as follows:
Helicopter
AIA
P835 (11) to
J1 (12)
P843 (13) to
J4 (14)
f. Install access panels L40 and R40 (TM 1-
1520-238-23).
g. Go to step 10 below.
9. Open MAINT LT circuit breaker (TM 1-1520-
238-23).
10. Proceed with maintenance task.
END OF TASK
470-003A
10
8
9
4
14
13
12
11
100-209A