TM 55-4920-403-20&PWARNINGThe shelter contains voltages that aredangerous if contacted. Before re-moving either electric cables or com-ponents, make certain electrical poweris completely disconnected. Do notconnect or disconnect power cableswhile energized. Install and connectgrounding rods before energizing shel-ter.k. Start generator and energize shops in thefollowing sequence:(1) Close (turn on) generator mainbreaker.(2) Close (turn on) power panel breaker.(3) Close (turn on) shelter main breaker.2-3. Instructions for Moving Shelter.a.Make suregenerator power is off,open main breaker,then disconnect powerc a b l e f r o m g e n e r a t o r p i g t a i l a n d s t o r eon power panel storage plate.b.Disconnect power cable from shelter.c.If necessary, retrieve from storage theECU mounting frame and install frame on shelterfloor with four hexagon-head capscrews and lock-washers.d. Remove environmental control unit fromshelter mounting shelf and place in ECU frame onshelter floor, then secure the environmental con-trol unit with web straps. (Refer to figure D-7.)e.Close ECU mounting shelf.f. Remove ground rod and save for reuse.g. Close shelter vent.h. Secure the power cable (item 2, figure D-4) under work table,i.Place all tools and components of theshop sets in drawers of the work table.i.All loose items to be transported in sheltermust be secured and strapped down.k. Close shelter for movement in accordancewith the instructions contained in TB 43-0124.2-4. Operation.a.Refer to appropriate technical manualsand manufacturer’s literature for operation ofgrinding machine.b. Remove tools from storage drawers inwork table as required for performing aviation unitmaintenance of aircraft -material. Return tools toproper storage location when not in use.2-2Change 2
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business