TM 55-4920-403-20&P
CAUTION
Be sure that power is off before testing
any circuit with an ohmeter.
(3) Test connector with a suitable volt-
meter for proper phase connections.
NOTE
ECU has 3 phase motors which will
ma/function if proper phase con -
nections are not maintained.
g.
Inside Electrical Outlets. Turn off circuit
breaker supplying power to the inside electrical
outlets. Remove cover plate (item 23, figure D-2),
remove screws securing receptacle (item 26, fig-
ure D-2) to box and remove wires from recep-
tacle. Install new receptacle connecting wires the
same as on the old one. Install mounting screws
and cover plate. Turn on circuit breaker and
check circuit for proper operation.
3-5. Major TOE Maintenance. Maintain all major
TOE items in accordance with applicable TMs,
some of which are called out in the remarks sec-
tion of the MAC chart.
3-4