Figure 1-40. Vibration Transducer
Type 4-128-0101, Exploded View
e. Insert pins of the Spanner Wrench, Part No.
a. Place the vibration transducer on the Torque
360284-3, into the two non-threaded holes in the
Plate Part No. 360284-4, or equivalent holding device.
bobbin assembly. C a r e f u l l y turn spanner wrench
counterclockwise, unscrewing bobbin assembly from
b. Remove the four screws and washers from the
the case.
cover using a 5/64 Allen wrench.
f. When bobbin assembly is hose from
case, re-
c. Carefully lift the cover away from the bobbin and
move the transducer from the torque plate
and care-
case assembly, taking care not to break the wires
fully remove bobbin assembly from the
case. Be
connecting the cable assembly to the terminals of the
careful not to allow the springs, magnet,
or sleeve
bobbin assembly.
to fall free.
d. Unsolder the cable assembly from the bobbin
g. Using Non-Magnetic Tweezers, Part No. 170267,
assembly, and remove gasket seal from the bobbin
carefully remove the lower spring, the magnet, and
and case assembly.