TM 55-1510-222-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
SECOND ENGINE START (BATTERY START)
(CONT)
11. Inverter switches - ON, check IN-
VERTER annunciator lights extin-
guished.
12. Second engine generator switch -
RESET, then ON.
13. Strobe beacon lights switch - DAY
or NIGHT as required.
ABORT START
1. Condition lever - FUEL CUTOFF.
2. Ignition and engine start switch -
STARTER ONLY.
3. TGT - Monitor for drop in temper-
ature.
4. Ignition and engine start switch -
OFF.
ENGINE CLEARING
1. Condition lever - FUEL CUTOFF.
2. Ignition and engine start switch -
OFF (1 minute minimum).
Do not exceed starter limitation of 40 sec-
onds ON and 15 minutes OFF, 40 seconds
ON, then 30 minutes OFF before additional
starter operation.
3. Ignition and engine start switch -
STARTER ONLY (15 seconds
minimum, 40 seconds maximum).
2-18