TM 55-1510-222-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
FIRST ENGINE START (BATTERY START)
(CONT)
If  ignition  does  not  occur  within  10  seconds
after  moving  condition  lever  to  LOW  IDLE,
initiate   ENGINE   CLEARING   procedure.   If
for  any  reason  a  starting  attempt  is  discon-
tinued,  the  entire  starting  sequence  must  be
repeated   after   allowing   the   engine   to   come
to  a  complete  stop  (1  minute  minimum).
5.  Condition  lever  (after  N1  RPM  sta-
bilizes,  12%  minimum)  -  LOW
IDLE.
E1,J1
Monitor  TGT  to  avoid  a  hot  start.  If  there
is  a  rapid  rise  in  TGT,  be  prepared  to  abort
the  start  before  limits  are  exceeded.  During
starting,  the  maximum  allowable  TGT  is
1000°C  for  five  seconds.  If  this  limit  is  ex-
ceeded,  use  ABORT  START  procedure  and
discontinue  start.  Enter  the  peak  tempera-
ture  and  duration  on  DA  Form  2408-13.
6.  TGT  and  N1  -  Monitor  (TGT
1000°C   maximum,   N1   61%   mini-
mum).
7.  Oil  pressure  -  Check  (60  PSI  mini-
mum).
E7-9
8.  Ignition  and  engine  start  switch  -
OFF,  after  TGT  peaks.
2-16