TM 55-1510-220-10
g.
Battery
Charge
Caution
Annunciator
Light
Illuminated.
If
the
BATTERY
CHARGE
caution
annunciator light illuminates during normal cruise flight,
perform the following:
(1.)
Loadmeter - Check; note indication.
(2.)
Battery switch - OFF.
(3.)
Loadmeter - Check. If loadmeter indicates
less that 2.5%, change (one needle width),
turn battery switch ON and monitor for
increasing load. If load continues to increase,
turn battery switch OFF.
NOTE
Circuit breakers should not be reset more
than once until the cause of the circuit
malfunction has been determined and
corrected. Do not reset dual fed bus feeder
circuit breakers.
Change 3 9-12.1 /(9-12.2 blank)