FIRST ENGINE START (BATTERY START) (CONT)
CAUTION
MoN1tor TGT to avoid a hot start. If there is a rapid rise in
TGT, be prepared to abort the start before limits are
exceeded. During starting, the maximum allowable TGT is
1000°C for five seconds. If this limit is exceeded, use ABORT
START procedure and discontinue start. Enter the peak
temperature and duration on DA Form 2408-13.
6. TGT and N1 - Monitor (TGT
1000°C maximum, N1 52% minimum).
7. Oil pressure - Check (60 PSI mini-
E4-6
mum).
8. Condition lever - HIGH IDLE.
E1
Monitor TGT as the condition lever is
advanced.
9. Ignition and engine start switch -OFF, after
TGT stabilized.
10. Generator switch - RESET, then ON.
SECOND ENGINE START (BATTERY START)