4-30. NVG MOUNTING System No. 2
LOCATION/ITEM
ACTION
REMARKS
INSTALLATION - Continued
b.
Measure 3 1/4-inch from top of visor housing
(1) and mark. Repeat the measurement and
marking 2-inches from the first mark. Draw a
line.
c.
Measure 1/4-inch from edge of visor lock
track (3) and mark. Repeat the measurement
and marking 2-inches from the first mark.
Draw a line.
d.
Measure 2 1/4-inch from edge of visor lock
track and mark. Repeat the measurement
and marking 2-inches from the first mark.
Draw a line.
e.
Clean area using silicon carbide paper. Sand
lightly and remove dust with a clean cloth
moistened with denatured alcohol.
Change 1 4-96