TM10-6640-216-13&P
4-33. REPAIR DISTILLATION UNIT.
This task covers:
a. Removal
b. Installation
INITIAL SET-UP:
ToolsRequired
General Mechanics Tool Kit, Appendix B, Item 1
Drill and Bit, Appendix B, Item 3
Rivet Gun, Appendix B, Item 2
Materials/PartsRequired
Rivets, Appendix F
GeneralSafety Instructions
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment
ensure all electrical power has been turned off. Death or serious
injury may occur from failure to do this.
REMOVAL
1.
Remove shield assembly. See figure 4-27.
a.
Unplug the condenser power cord from the wall receptacle.
b.
Remove ten shield assembly mounting screws.
c.
Lift unit forward and disconnect shield assembly from the condenser assembly.
d.
Remove defective shield assembly and attached angle iron to a working surface.
e.
Drill out ten blind pop rivets from the angle iron.
f.
Remove angle iron from shield assembly, and remove shield assembly.
2.
Remove condenser assembly. See figure 4-27.
a.
Unplug the condenser power cord from the wall receptacle.
b.
Remove ten shield assembly mounting screws.
c.
Lift shield assembly and disconnect shield assembly from the condenser assembly.
d.
Remove shield assembly and attached angle iron to working area.
e.
Remove fourteen condenser assembly mounting screws.
f.
Remove drain line from back of condenser.
4-91