TM10-6640-216-13&P
4-24. REMOVE/INSTALL CORROSION TEST BATH.
This task covers:
a. Removal
b. Installation
INITIAL SET
Tools Required
General Mechanics Tool Kit, Appendix B, Item 1
Drill and Bit, Appendix B, Item 3
Rivet Gun, Appendix B, Item 2
Materials/Parts Required
Rivets, Appendix F
General Safety Instructions
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment
ensure all electrical power has been turned off. Death or serious
injury may occur from failure to do this.
REMOVAL
Remove corrosion test bath. See figure 4-28.
a.
Unplug corrosion test bath power cord.
b.
Remove fourteen mounting screws.
c.
Disconnect drain hose.
d.
Remove bath and attached angle iron to a working surface.
e.
Drill out twelve blind pop rivets from the angle iron.
f.
Remove angle iron from corrosion test bath.
INSTALLATION
Install corrosion test bath. See figure 4-28.
a.
On a working surface place the angle iron onto the new corrosion test bath and drill
twelve holes.
b.
Rivet twelve .188 in. diameter blind pop rivets, six on each side connecting angle iron, to
the bath.
c.
Place the bath and attached angle iron on countertop of storage cabinet No. 3.
d
Connect drain hose.
e.
Install fourteen mounting screws, seven on each side of unit, attaching corrosion test
bath to countertop.
f.
Plug in the bath power cord and verify proper operation.
4-94