TM 55-1510-222-CL
10.
BATTERY CHARGE annunciator - Check on.
11.
Inverter switches ON, - Check INVERTER annunciators off.
12.
Second engine generator switch - RESET, then ON.
13.
Beacon light - Reset. Then on.
ABORT START PROCEDURE
1.
Condition lever - FUEL CUTOFF.
2.
Ignition and engine start switch - STARTER ONLY
3.
TGT Monitor for drop in temperature.
4.
Ignition and engine start switch - OFF.
ENGINE CLEARING PROCEDURE
1.
Condition lever - FUEL CUTOFF.
2.
Ignition and engine start switch - OFF (1 minute minimum).
3.
Ignition and engine start switch - STARTER ONLY.
4.
Ignition and engine start switch - OFF.
* FIRST ENGINE START (GPU START)
1.
INS - As required.
2.
Exterior light switches - As required.
3.
Propeller area - Clear.
4.
#1 ignition and engine start switch - START IGNITION.
5.
Condition lever (after N1, RPM passes 13% minimum) - LOW IDLE.
6.
TGT and N1 - Monitor (TGT 1000°C maximum)
N-11