TM 5-6630-218-10
CAUTION
Do not remove the test pad from its sealed package until you are ready to place it
into the monitor. Do not allow any discrete water droplets to come into contact
with the pad. Do not expose the pad to humidity or the atmosphere. Contact
with these elements may effect the accuracy of the test results.
c.
The pad has an orange, fluffy-textured top and a white backing.
Insert the pad orange-side up towards the inlet of the monitor (the orange
side should be facing upstream of the fuel flow). See Figure 2.29.
Figure 2.29 Inserting the Free Water Test Pad in the Monitor
2.5.3
d.
Reassemble (snap the top on) the monitor.
Inserting the Stainless Steel Monitor into Sampler Assembly
a.
Unscrew the sampler cover and insert the stainless steel monitor
containing the free-water test pad (inlet side facing upstream). Screw the
sampler case into the sampler cover (to a snug hand-tightness). See Figure
2.30.
2 - 33