2.4.9 Finding the Corrected
Density
TM 5-6630-218-10
API Gravity, Temperature, and Relative
a.
Using the gravity calculator attached to the test kit placard,
determine the corrected API: select the appropriate type of fuel being
tested and turn the computer slide to match the recorded API gravity with
the recorded temperature.
b.
Read and record the corrected gravity, temperature, and relative
density indicated at the 60° mark on the computer scale (Figure 2.20). Refer
to the example shown on the gravity calculator as well.
Figure 2.20 Reading Corrected API Gravity, Temperature, and
Relative Density
c.
Compare the readings to the established site standards and record
the test results. Determine if the fuel sample satisfies specified site
standards.
d.
Dispose of excess fuel safely and according to site regulations.
2-22