T.O. 1-1A-9
TABLE 4-14. WELDING RODS FOR JOINING WROUGHT TO WROUGHT ALLOY.
CODE 1 = UseAZ92A or AZ61A rod - AZ92A preferred. AZ61A cheaper, generally satisfactory, but subject to weld
cracking.
2 = Use EZ33A rod, particularly when two alloys for elevated temperature use are to be welded. Use AZ92A or
AZ61A when an elevated and room temperature alloy are welded together.
X = Welding not recommended.
TABLE 4-15. WELDING RODS FOR JOINING CAST TO WROUGHT ALLOYS.
CODE 1 = Same as for Table 4-14
2 = Same as for Table 4-14
X =- Same as for Table 4-14
TABLE 4-16. WELDING RODS FOR JOINING CAST TO CAST ALLCYS.
4-28