TM 1-1510-225-CL
E-10
5. BATT switch ON.
6. GEN switches (individually) RESET, then ON.
7. Circuit breakers Check for indication of defective
circuit.
8. Essential electrical equipment On (individually
until fire source is isolated).
9. Land as soon as practicable.
SMOKE AND FUME ELIMINATION
1. Crew oxygen masks 100% and on.
2. Passenger oxygen ON.
3. BLEED AIR VALVE switches PNEU & ENVIR
OFF.
4. VENT BLOWER switch AUTO.
5. AFT BLOWER switch OFF.
6. CABIN TEMP MODE switch OFF.
7. If smoke and fumes are not eliminated, CABIN
PRESS Switch DUMP.
NOTE
Opening storm window, after depressurizing,
will facilitate smoke and fume removal.
8. Passenger oxygen masks Check. Confirm that
all
passengers
are
receiving
supplemental
oxygen.
9. Engine oil pressure Monitor.
FUEL SYSTEM
FUEL PRESS WARNING LIGHT ILLUMINATED
1. STANDBY PUMP switch ON.