TM 1-1510-225-10
3C-30
Table 3C-1. Autopilot System Limits (Continued)
MODE
CONTROL OR SENSOR
PARAMETER
VALUE
Pitch Sync
TCS Switch on Control Wheel
Pitch Attitude Command
± 20°
ALT Hold
Air Data Computer
ALT Hold Engage Range
0 to 50,000 ft
ALT Hold Engage Error
± 20 ft
Pitch Limit
± 20°
Pitch Rate Limit
Function of (TAS)
VS Hold
Air Data Computer
VERT
Speed
Engage
Range
0 to ± 6000 ft/min
Engage Error
± 30 ft
Pitch Limit
± 20°
Pitch Rate Limit
Function of (TAS)
IAS Hold
Air Data Computer
IAS Engage Range
80 to 450 knots
IAS Hold Engage Error
± 5 knots
Pitch Limit
± 20°
Pitch Rate Limit
Function of (TAS)
ALT Pre-select
Air Data Computer
Pre-select Capture Range
0 to 50,000 ft
Maximum Vertical Speed for
Capture
± 4000 ft/min
Maximum
Gravitational
Force
± .2g
During Capture Maneuver
Pitch Limit
± 20°
Pitch Rate Limit
Function of (TAS)
1. Pitch Wheel
2. BANK LIMIT Selector/Light
3. SOFT RIDE Switch
4. TURN Knob
5. Yaw Damp ENGAGE Push Button
6. Autopilot ENGAGE Push Button
7. Elevator TRIM Annunciator
Figure 3C-14. Autopilot Controller