TM 1-1510-224-CL
NAC LOW ANNUNCIATOR ILLUMINATED
1.
Land as soon as practicable.
ELECTRICAL SYSTEM EMERGENCIES
DC GEN ANNUNCIATOR ILLUMINATED
(1.) GENERATOR switch - OFF, RESET, then ON.
(2.) GENERATOR switch (no reset) - OFF.
(3.) MISSION CONTROL switch - ORIDE.
(4.) Operating loadmeter - 100% maximum.
BOTH DC GEN ANNUNCIATORS ILLUMINATED (RESET
FAILED)
(1.) All nonessential equipment - Off.
2.
Land as soon as practicable.
EXCESSIVE LOADMETER INDICATION (OVER 100%)
(1.) BATTERY switch - OFF (monitor loadmeter).
(2.) Loadmeter
over
100%
-
Nonessential
electrical
equipment off.
(3.) Loadmeter under 100% - BATTERY switch ON.
INVERTER ANNUNCIATOR ILLUMINATED
(1.) Affected INVERTER switch - Off.
INST AC ANNUNCIATOR ILLUMINATED
The following systems will be affected:
NAV #1
NAV #2
Heading #2
#1 torquemeter
#2 torquemeter
Pilot's EFIS
Copilot's EFIS