TM 1-1510-233-CL
N-6
3. ENG START switch START - IGNITION. IGN
ON annunciator should illuminate and FUEL
PRESS annunciator should extinguish.
4. CONDITION lever (after N1 RPM passes 13%
minimum) LOW IDLE.
5. TGT and N1 Monitor (TGT 1000 C maxi-
mum.
6. Oil pressure Check (60 PSI minimum).
7. ENG START switch OFF after TGT peaks.
8. CONDITION levers HIGH IDLE. Monitor
TGT as CONDITION lever is advanced.
9. PROP levers HIGH RPM.
10. INVERTER switches ON, check INVERTER
annunciators off.
11. Current limiters Check.
12. Generator switch Second switch RESET,
then ON.
13. BEACON lights switch Reset, then as re-
quired.
ABORT START PROCEDURE
1. CONDITION lever FUEL CUTOFF.
2. ENG START switch STARTER ONLY.
3. TGT Monitor for drop in temperature.
4. ENG START switch OFF.
ENGINE CLEARING PROCEDURE
1. CONDITION lever FUEL CUTOFF.
2. ENG START switch OFF (15 minutes mini-
mum).