TM 1-1510-233-CL
N-8
4. TGT and N1 Monitor (TGT 1000 C maxi-
mum).
5. Oil pressure Check (60 PSI minimum).
6. ENG START switch OFF after TGT peaks.
7. AC and DC GPU units Disconnect (check air-
craft external power and mission external pow-
er annunciators extinguished).
8. CONDITION levers HIGH IDLE.
9. PROP levers HIGH RPM.
10. #1 and #2 INVERTER switches ON. Check
INVERTER annunciators extinguished.
11. GENERATOR switch (1) Reset, then ON.
12. Current limiters Check.
13. GENERATOR switch Second switch reset,
then on.
14. BEACON lights switch Reset, then on.
BEFORE TAXIING
*1. BRAKE DEICE switch Check and set as re-
quired.
*2. CABIN AIR MODE and TEMP controls Set
as desired.
3. AC/DC power Check.
*4. AUTO PLT POWER switch ON.
*5. AVIONICS MASTER POWER switch ON.
*6. #1 and #2 EFIS POWER switches ON.
*
7.
Mission control panel switches Set and
checked as required.