TM 55-1510-221-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
*8.
Battery condition - Check as re-
quired. If BATTERY CHARGE
light is illuminated during engine
shutdown, monitor battery amme-
ter (mission control panel), for de-
creasing current Battery condition
is unsatisfactory if BATTERY
CHARGE light remains illuminate-
ed and charge current falls to de-
crease between checks.
9. Avionics master switch - OFF.
10. TGT - Check TGT must be 660°C
or below for one minute prior to
shutdown.
11. Propeller levers - FEATHER.
CAUTION
Monitor TGT during shutdown. If sustained
combustion is observed, proceed immediate-
ly to ABORT START procedure
12. Condition levers - FUEL CUT-
OFF
WARNING
Do not turn EXTERIOR LIGHTS OFF un-
til propeller's rotation has stopped
13. Exterior lights - OFF
14 Master panel lights - OFF
15 Key lock switch - OFF
2-65