TM 55-1510-221-10
NOTE
Replace any lamp that does not illumi-
nate when pressed. If none of the indicat-
ing lamps illuminate, return test set to
AVUM.
b. Rotate TEST SEQUENCE switch
clockwise to TS RESET position. No
visual indication will occur.
c.
Rotate TEST SEQUENCE switch
clockwise to SV SELF TEST position.
STRAY VOLTAGE lamp (red) will
illuminate.
d. Rotate TEST SEQUENCE switch
clockwise to next position, TS RESET.
STRAY VOLTAGE lamp (red) will
extinguish.
e.
Rotate TEST SEQUENCE switch
clockwise to next position, STRAY
VOLT. STRAY VOLTAGE lamp (red)
should not illuminate.
f. Rotate TEST SEQUENCE switch
clockwise to next position, SYS NOT
RESET. SYS NOT RESET lamp
(amber) should not illuminate. If lamp
illuminates, press and release MAN-
UAL SYSTEM RESET switch and SYS
NOT RESET lamp should then extin-
guish.
NOTE
When the MANUAL SYSTEM RESET
switch is pressed and released, and 28
volts DC power has been applied, the
sequencer switch inside the dispenser
assembly resets, making an audible sound
as it rotates. If the sequencer switch has
been previously reset or if the switch is in
position 12 or 24, there will be no such
sound.
g. Rotate TEST SEQUENCE switch
clockwise to next position,
DISP
COMPL.
19.
Press pilot CHAFF DISP switch once, Press
copilot CHAFF DISP switch once. On DCP,
for each depressing, the CHAFF counter
should count down by an increment of one.
20.
On DCP, set MAN-PGRM switch to PGRM
position.
21.
Press any one of CHAFF DISP switches in
aircraft. On DCP, the number shown on
22.
23.
CHAFF counter should decrease in accor-
dance with the program set on the EM.
Repeatedly press other CHAFF DISPENSE
switch until CHAFF counter on DCP reads
00.
On test set, observe DISPENSE COM-
PLETE lamp (green) is illuminated and then
perform the following operations:
a.
Rotate TEST SEQUENCE switch
counter-clockwise to SYS NOT RESET
position.
SYS NOT RESET lamp
(amber) will illuminate.
b.
Press and release MANUAL SYSTEM
RESET switch. SYS NOT RESET lamp
(amber) will extinguish.
NOTE
When the MANUAL SYSTEM RESET
switch is pressed and released, and 28
volts DC power has been applied, the
sequencer switch inside the dispenser
assembly resets, making an audible sound
as it rotates. If the sequencer switch has
been previously reset or if the switch is in
position 12 or 24, there will be no such
sound.
c.
Rotate TEST SEQUENCE switch
counter-clockwise to STRAY VOLT
position. STRAY VOLTAGE lamp
(red) should not illuminate.
d. Rotate TEST SEQUENCE switch
counter-clockwise to START/HOME
position.
NOTE
When the TEST SEQUENCE switch is
turned to the OFF position, the DIS-
PENSER COMPLETE lamp will extin-
guish, the STRAY VOLTAGE lamp will
illuminate and then will extinguish when
the OFF position is reached.
24. Install safety pins.
25.
Disconnect test set power cable.
26.
Remove M-91 test set from dispenser assem-
bly and restore in carrying case along with
the power cable and hexagonal wrench.
27. On DCP, set ARM-SAFE switch to SAFE
position.
28.
On DCP, reset CHAFF counter to 30.
4-8