TM 55-1510-220-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
3.
Condition lever (after N I RPM passes 12% minimum) - LOW IDLE.
4.
TGT and N1 - Monitor (TGT 1000°C maximum, NI 52% minimum).
5.
Oil pressure - Check (60 PSI mini mum)
E4-7
6.
Ignition and engine start switch -OFF, after 50% N1.
7.
Battery charge light - Check (light should illuminate approximately 6 seconds after generator is brought on
line. Light should extinguish within 5 minutes following a normal engine start on battery).
8.
Inverter switches - ON, check INVERTER lights extinguished.
9.
Second engine generator switch - RESET, then ON.
10. Strobe beacon lights switch - DAY or NIGHT as required.
11. Condition levers - As required.
ABORT START
1.
Condition lever - FUEL CUTOFF.
2.
Ignition and engine start switch - STARTER ONLY.
3.
TGT - Monitor for drop in temperature.
4.
Ignition and engine start switch - OFF.
2-17