TM 55-1510-220-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
FIRST ENGINE START (BATTERY START) (CONT)
CAUTION
Monitor TGT to avoid a hot start. If there is a rapid rise in
TGT, be prepared to abort the start before limits are exceeded.
During starting, the maximum allowable TGT is 1000°C for
five seconds. If this limit is exceeded, use ABORT START
procedure and discontinue start. Enter the peak temperature
and duration on DA Form 2408-13.
7.
TGT and N1 - Monitor (TGT 1000°C maximum, N1 52% minimum).
8.
Oil pressure - Check (60 PSI minimum).
9.
Ignition and engine start switch OFF, after 50% N1.
10.
Condition lever - HIGH IDLE. Monitor TGT as the condition lever is advanced.
11.
Generator switch - RESET, then ON.
SECOND ENGINE START (BATTERY START)
1.
Propeller - Clear.
2.
Ignition and engine start switch - ON. Propeller should begin to rotate and associated
A1-7
IGN ON light should illuminate. Associated FUEL PRESS light should extinguish.
2-16