TM 55-1510-220-10
NOTE
When the MANUAL SYSTEM RESET
switch is pressed and released, and 28 volts
I)C power has been applied, the sequencer
switch inside the dispenser assembly resets,
making an audible sound as it rotates. If
the sequencer switch has been previously
reset or if the switch is in position 12 or 24,
there will be no such sound.
c.
Rotate TEST SEQUENCE switch counterclockwise
to STRAY VOLT position. STRAY VOLTAGE
lamp (red) should not illuminate.
d.
Rotate TEST SEQUENCE switch counter-clockwise
to START/HOME position.
NOTE
When the TEST SEQUENCE switch is
turned to the START/HOME position, the
DISPENSER
COMPLETE
lamp
will
extinguish, the STRAY VOLTAGE lamp
will illuminate and then will extinguish
when passing through the TS RESET
position.
15. On CHAFF dispenser assembly, assure that
C-F selector switch is in C (chaff) position.
16. Remove M-91 test set from first dispenser
assembly.
17. Connect M-91 test set to breech assembly of
second dispenser assembly. Secure both
mounting studs uniformly hand tight using
ball hexagonal key screwdriver provided in
test set carrying case.
NOTE
When the test set is installed on the
dispenser assembly and 28 volts DC
aircraft power has been applied, the
sequence switch inside the dispenser
assembly resets, making an audible sound
as it rotates. There will be no such sound if
the sequencer switch has been previously
reset or if switch is in position 12 or 24.
NOTE
On test set, TS PWR ON lamp (clear)
illuminates
and
remains
illuminated
through the test sequence until aircraft
power to test set (via test set power cable)
is disconnected or shut off.
18. Perform the following operations on the M91
test set:
a.
Press to test all four lamps on test set. Each lamp
will illuminate.
NOTE
Replace any lamp that does not illuminate
when pressed. If none of the indicating
lamps illuminate, return test set to AVUM.
b.
Rotate TEST SEQUENCE switch clockwise to TS
RESET position. No visual indication will occur.
c.
Rotate TEST SEQUENCE switch clockwise to SV
SELF TEST position. STRAY VOLTAGE lamp
(red) will illuminate.
d.
Rotate TEST SEQUENCE switch clockwise to next
position, TS RESET. STRAY VOLTAGE lamp (red)
will extinguish.
e.
Rotate TEST SEQUENCE switch clockwise to next
position, STRAY VOLT. STRAY VOLTAGE lamp
(red) should not illuminate.
f.
Rotate TEST SEQUENCE switch clockwise to next
position, SYS NOT RESET. SYS NOT RESET lamp
(amber) should not illuminate. If lamp illuminates,
press and release MANUAL SYSTEM RESET
switch and SYS NOT RESET lamp should then
extinguish.
NOTE
When the MANUAL SYSTEM RESET
switch is pressed and released, and 28 volts
DC power has been applied, the sequencer
switch inside the dispenser assembly resets,
making an audible sound as it rotates. If
the sequencer switch has been previously
reset or if the switch is in position 12 or 24,
there will be no such sound.
4-7