TM 551510-220-10
6.
Provide aircraft power to DCP by setting M-
130 POWER circuit breaker to ON position.
7.
On DCP, press ARM lamp. Lamp will
illuminate. Release ARM lamp. Lamp will
extinguish.
8.
On DCP, set FLARE counter to 30 CHAFF
COUNTER to 30 and MAN-PGRM switch to
MAN position.
9.
On DCP, set ARM-SAFE switch to ARM.
ARM lamp will illuminate.
NOTE
When the test set is installed on the
dispenser assembly and 28 volts DC
aircraft power has been applied, the
sequencer switch inside of dispenser
assembly resets, making an audible sound
as it rotates. There will be no such sound if
the sequencer switch has been previously
reset or if switch is in position 12 or 24.
NOTE
On test set, TS PWR ON lamp (clear)
illuminates
and
remains
illuminated
throughout the test sequence until aircraft
power to test set (via test set power cable)
is disconnected or shut off.
10. Set mission chaff program on EM.
11. Perform the following operations on the M91
test set:
a.
Press to test the remaining three lamps on test set.
Each lamp will illuminate.
NOTE
Replace any lamp that does not illuminate
when pressed. If none of the indicating
lamps illuminate, return test set to AVUM.
b.
Rotate TEST SEQUENCE switch clockwise to the
next position, TS RESET. No visual indication will
occur.
c.
Rotate TEST SEQUENCE switch clockwise to SV
SELF TEST position. STRAY VOLTAGE lamp
(red) will illuminate.
d.
Rotate TEST SEQUENCE switch clockwise to next
position, TS RESET. STRAY VOLTAGE lamp (red)
will extinguish.
e.
Rotate TEST SEQUENCE switch clockwise to next
position, STRAY VOLT. STRAY VOLTAGE lamp
(red) should not illuminate.
f.
Rotate TEST SEQUENCE switch clockwise to next
position, SYS NOT RESET. SYS NOT RESET lamp
(amber) should not illuminate. If lamp illuminates,
press and release MANUAL SYSTEM RESET
switch and SYS NOT RESET lamp should then
extinguish.
NOTE
When the MANUAL SYSTEM RESET
switch is pressed and released, and 28 volts
DC power has been applied, the sequencer
switch inside the dispenser assembly resets,
making an audible sound as it rotates. If
the sequencer switch has been previously
reset or if the switch is in position 12 or 24,
there will be no such sound.
g.
Rotate TEST SEQUENCE switch clockwise to next
position, DISP COMP.
12. Press FLARE DISP switch once. For each
depressing, the FLARE counter on DCP
should count down in groups of three.
13. On DCP, raise RIPPLE FIRE switch guard
and set toggle switch to up position until
FLARE counter counts down to 00. Return
switch guard to down position. On DCP,
reset FLARE counter back to 30.
DISPENSER COMPLETE lamp (green) on
test set will illuminate.
14. Perform the following operations on the M91
test set:
a.
Rotate TEST SEQUENCE switch counter-
clockwise to SYS NOT RESET position.
SYS NOT RESET lamp (amber) will
illuminate. DISPENSER COMPLETE lamp
(green) will remain illuminated.
b.
Press and release MANUAL SYSTEM
RESET switch. SYS NOT RESET lamp
(amber) will extinguish.
4-6