TM 55-1510-220-10
(8)
PWR indicator. This indicator (white)
illuminates when power is applied to the TSEC/ KY-75
system and the PWR/FILL switch is set to one of the
numbered fill positions.
(9)
FILL connector. This connector, located on
the front of the TSEC/KY-75 control panel allows connection
to a fill device.
(10)
Processor connector. This connector, located
on the back of the TSEC/KY-75 control unit, allows
connection of the control unit to the processor via a cable.
c.
TSEC/KY-75 Operating Procedures.
(1)
TSEC/KY-75 system turn-on procedure:
1.
PWR/FILL switch (fig. 3-8) Set to
any fill register number. Check that
PWR indicator light is illuminated.
2.
PLAIN/CIPHER
switch
CIPHER.
Check that CIPHER indicator light is
illuminated.
3.
PWR/FILL switch Set to each fill
register (1 thru 3). If the position has
not already been filled a steady alarm
tone will be heard.
(2)
Filling TSEC/KY-75 using general purpose
tape reader (KOI-18/TSEC).
1.
FILL connector Connect to tape reader
using fill cable (ON5124204).
2.
PWR/FILL switch Set to register to be
filled.
3.
Insert the tape leader into the IN slot
on tape reader. Line up tape feed
holes with the white dots on tape
reader.
4.
RMT-LOCAL-SIG CLR switch Set to
SIG CLR clear then release.
5.
Pull tape through tape reader at a
moderate rate. The steady alarm tone
heard over the headset should stop,
indicating a successful fill.
6.
Repeat procedure for each register to
be filled.
(3)
Filling TSEC/KY-75 system using transfer-
device KYK-13/TSEC.
1.
Verify that the transfer device contains
the variables in its registers that are
indicated on its writing surface by:
a.
Transfer device mode switch OFF/CK.
b.
PWR/FILL switch Set to register to be
verified.
c.
Transfer device initiate button Press
and release. Transfer device indicator
light will flash if the register contains
a variable.
d.
Repeat procedure for each transfer
device register to be verified.
NOTE
Insure that the rubber grommet is in
the KYK-13/TSEC P1 connector and
that
the
TSEC/KY-75
PLAIN/CIPHER switch is in the
CIPHER position.
2.
FILL connector Connect to transfer
device (either directly or with a fill
cable).
3.
Transfer device FILL switch Set to
register containing variable to be
transferred.
4.
Transfer device MODE switch ON.
5.
RMT/LOCAL/SIG CLR switch (fig. 3-
8) Set to SIG CLR and release. Parity
indicator light on transfer device
should flash, and the steady alarm tone
in the headset should cease, indicating
a successful transfer of the variable.
6.
Repeat procedure for each TSEC/ KY-
75 register to be filled.
7.
Transfer device mode switch Set to
OFF/CK
and
disconnect
from
TSEC/KY-75.
(4)
TSEC/KY-75
secure
voice
operating
procedure:
1.
PLAIN/CIPHER switch (fig. 3-8)
CIPHER.
Check
that
CIPHER
indicator light illuminates.
3-18
