TM 55-1510-219-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
ammeter
(mission
control
panel),
for
decreasing current.
10. Avionics master switch - OFF.
11. TGT - Check. TGT must be 660°C or below
for one minute prior to shutdown.
12. Propeller levers - FEATHER.
CAUTION
Monitor TGT during shutdown. If sustained combustion is
observed, proceed immediately to ABORT START procedure.
13. Condition levers - FUEL CUT-OFF.
Do not turn EXTERIOR LIGHTS OFF until propeller's rotation
has stopped.
14. Exterior lights - OFF.
15. Master panel lights - OFF.
16. Key lock switch - OFF.
17. Oxygen system - As required.
BEFORE LEAVING AIRCRAFT
1. Wheels - Chocked.
2. Parking brake - As required.
2-63