TM 55-1510-219-10
NOTE
When the test set is installed on
the dispenser assembly and 28
volts DC aircraft power has been
applied, the sequence switch
inside the dispenser assembly
resets, making an audible sound
as it rotates. There will be no
such sound if the sequencer
switch has been previously reset
or if switch is in position 12 or 24.
NOTE
On test set, TS PWR ON lamp
(clear) illuminates and remains
illuminated
through
the
test
sequence until aircraft power to
test set (via test set power cable)
is disconnected or shut off.
18.
Perform the following operations on the M-91
test set: a. Press to test all four lamps on test
set. Each lamp will illuminate.
NOTE
Replace any lamp that does not
illuminate when pressed. If none
of the indicating lamps illuminate,
return test set to AVUM.
b.
Rotate TEST SEQUENCE switch
clockwise to TS RESET position.
No visual indication will occur.
c.
Rotate TEST SEQUENCE switch
clockwise
to
SV
SELF
TEST
position. STRAY VOLTAGE lamp
(red) will illuminate.
d.
Rotate TEST SEQUENCE switch
clockwise to next position, TS
RESET. STRAY VOLTAGE lamp
(red) will extinguish.
e.
Rotate TEST SEQUENCE switch
clockwise to next position, STRAY
VOLT. STRAY VOLTAGE lamp
(red) should not illuminate.
f.
Rotate TEST SEQUENCE switch
clockwise to next position, SYS
NOT RESET. SYS NOT RESET
lamp (amber) should not illuminate.
If
lamp
illuminates,
press
and
release MANUAL SYSTEM RESET
switch and SYS NOT RESET lamp
should then extinguish.
NOTE
When
the
MANUAL
SYSTEM
RESET switch is pressed and
released, and 28 volts DC power
has been applied, the sequencer
switch
inside
the
dispenser
assembly
resets,
making
an
audible sound as it rotates. IF the
sequencer
switch
has
been
previously reset or if the switch is
in position 12 or 24, there will be
no such sound.
g.
Rotate TEST SEQUENCE switch
clockwise to next position, DISP
COMPL.
19.
Press pilot CHAFF DISP switch once. Press
copilot CHAFF DISP switch once. On DCP, for
each depressing, the CHAFF counter should
count down by an increment of one.
20.
On DCP, set MAN-PRGM switch to PRGM
position.
21.
Press any one of CHAFF DISP switches in
aircraft. In DCP, the number shown on CHAFF
counter should decrease in accordance with the
program set on the EM.
22.
Repeatedly press other CHAFF DISPENSE
switch until CHAFF counter on DCP reads 00.
23.
On test set, observe DISPENSE COMPLETE
lamp (green) is illuminated and then perform the
following operations:
a.
Rotate TEST SEQUENCE switch
counter-clockwise
to
SYS
NOT
RESET position. SYS NOT RESET
lamp (amber) will illuminate.
b.
Press
and
release
MANUAL
SYSTEM RESET switch. SYS NOT
RESET
lamp
(amber)
will
extinguish.
NOTE
When
the
MANUAL
SYSTEM
RESET switch is pressed and
released, and 28 volts DC power
has been applied, the sequencer
switch
inside
the
dispenser
assembly
resets,
making
an
audible sound as it rotates. If the
sequencer
switch
has
been
previously reset or if the switch is
in position 12 or 24, there will be
no such sound.
c.
Rotate TEST SEQUENCE switch
counter-clockwise to STRAY VOLT
position. STRAY VOLTAGE lamp
(red) should not illuminate.
4-8