TM 10-8415-206-12&P
4-8. ORGANIZATIONAL MAINTENANCE TROUBLESHOOTING - Continued
Table 4-2. Organizational Maintenance Troubleshooting Chart
MALFUNCTION
TEST or INSPECTION
CORRECTIVE ACTION
1. VISOR CANNOT BE RAISED OR LOWERED.
Step 1. Inspect for defective visor lock.
Replace visor lock per paragraph 4-9.
Step 2. Check for improperly installed visor lock.
Make certain lockstem has been rotated 900.
Step 3. Inspect for defective visor.
Replace visor per paragraph 4-11.
Step 4. Inspect for missing or defective spacer(s).
Replace spacer(s) per paragraph 4-12.
Step 5. Inspect for defective visor tracks.
Replace visor tracks per paragraph 4-12.
Step 6. Inspect for defective visor housing.
Replace visor housing per paragraph 4-10.
2. UNABLE TO ADJUST EAR CUP COMPRESSION.
Step 1. Inspect for worn or defective tension cross straps.
Replace per paragraph 4-14.
Step 2. Ear cup spacers are required or are defective.
Replace per paragraph 4-22.
3. UNABLE TO ADJUST CHIN STRAP.
Inspect for defective chin strap.
Replace defective chin strap per paragraph 4-13.
4-7