TM10-6640-216-13&P
5-11. REMOVE/INSTALL WATER PUMP AND MOTOR - continued.
WARNING
Serious injury to personnel or damage to equipment may occur unless
two or more personnel are used to remove water pump and motor
because of weight of water pump and motor.
i.
Remove the water pump and motor to a working surface.
j.
Remove water pump suction and discharge fittings.
k.
Remove teflon tape from pipe and fittings.
INSTALLATION
Install Water Pump and Motor (Figure 5-7).
a.
Place water pump on working surface.
b.
Apply teflon tape to all male fittings.
pipe thread.
Be sure to wrap teflon tape in same direction of
c.
Install water pump suction and discharge fittings.
WARNING
Serious injury to personnel or damage to equipment may occur unless
two or more personnel are used to install water pump and motor
because of weight of water pump and motor.
d.
Install new water pump and motor into storage cabinet 4.
e.
Mount water pump with four flat washers, lockwashers, and mounting nuts.
f.
Connect reducer fittings on discharge line from pump.
g.
Connect union on suction line from utility box.
h.
Connect suction hose to pump.
i.
Connect pump electrically to pressure switch and remove tags.
5-19/(5-20 Blank)