TM 1-1510-225-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
13. POWER levers - IDLE.
14. PROP levers - FEATHER.
Monitor ITT during shutdown. If sustained com-
bustion is observed, proceed immediately to Abort
Start procedure.
15. CONDITION levers - FUEL CUT-
OFF.
16. Oxygen system - Off.
Do not turn exterior lights off until propeller rota-
tion has stopped
17. Exterior lights switches - Off.
18. MASTER PANEL LIGHTS switch -
OFF.
19. AVIONICS MASTER PWR switch -
OFF.
20. MASTER SWITCH - OFF.
BEFORE LEAVING AIRCRAFT
NOTE
Release brakes after chocks are in place (ramp
conditions permitting).
1. Wheels - Chocked.
2. PARKING BRAKE - As required.
2-69