TM 1-1510-225-CL
P-8
VACUUM AND PNEUMATIC SYSTEM
1. LEFT BLEED AIR VALVE OFF.
a. Pneumatic and suction pressures remain
normal.
b. L BL AIR OFF annunciator illuminates.
c. Both BL AIR FAIL annunciators remain
extinguished.
2. RIGHT BLEED AIR VALVE OFF.
a. Pneumatic and suction pressures read zero.
b. Both BL AIR OFF and BL AIR FAIL
annunciators illuminated.
3. LEFT BLEED AIR VALVE ON.
a. Pneumatic and suction pressures return to
normal.
b. Both BL AIR FAIL annunciators extinguished.
c. L BL AIR OFF annunciator extinguished.
4. RIGHT BLEED AIR VALVE ON.
a. R BL AIR OFF annunciator extinguished.
AUTOMATIC FLIGHT CONTROL SYSTEM
1. Autopilot
controller
TRIM
UP,
TRIM
DN
annunciators Check not illuminated. A steady
illumination of TRIM UP or TRIM DN annunciator
indicates that automatic synchronization is not
functioning and autopilot should not be engaged.
2. Turn knob In center detent position.
3. Elevator trim control switch ON.
4. Control wheel To mid travel.