TM 1-1510-225-CL 
E13 
BATTERY 
CHG 
ANNUNCIATOR
ILLUMINATED 
DURING 
GROUND
OPERATIONS 
 
1.  One generator  OFF. 
 
2.  Voltmeter  Indicating 28 volts. 
 
3.  Momentarily  turn  battery   OFF    Note  change  in 
loadmeter indication. 
BATTERY 
CHG 
ANNUNCIATOR
ILLUMINATED IN FLIGHT 
 
1.  BATT  OFF. 
 
2.  BATTERY     CHG     annunciator          Check.          If
extinguished,   continue   flight.      If   light   remains
illuminated, land as soon as practicable. 
GENERATOR OVERHEAT  F3 
 
1.  GEN  OFF. 
 
2.  Electrical load  Check. 
 
3.  Current limiters  Check. 
CURRENT LIMITER CHECK 
 
1.  If Both   DC  GEN  annunciators  are  illuminated   
Individually  press  each  volt/loadmeter  switch and
observe  voltage.    If  generator  voltage  is  not  seen 
on voltmeter, that current limiter has burned open.
 
2.  If one  DC GEN annunciator is illuminated   Press
both volt/loadmeter switches and observe voltage.
If  generator  voltage  is  not  seen  on  the  affected
side,  one  or  more  current  limiters  have  burned
open.      If   battery   voltage   is   not   seen   on   the
affected side, the current limiter for that side has
burned open.