TM 1-1510-225-CL 
E12 
 
3.  Operating loadmeter  100% maximum. 
BOTH DC GEN LIGHTS ILLUMINATED 
 
1.  All nonessential equipment  Off. 
 
2.  Land as soon as practicable. 
O 
3.  Ferry   fuel       Transfer   using   wobble   pump   as
required. 
EXCESSIVE 
LOADMETER 
INDICATION
(OVER 100%) 
 
1.  BATT switch  OFF (monitor loadmeter). 
IF LOADMETER STILL INDICATES ABOVE 100%: 
 
2.  Nonessential electrical equipment  Off. 
IF LOADMETER INDICATES 100% OR BELOW: 
 
3.  BATT switch  ON. 
INVERTER WARNING LIGHT ILLUMINATED 
 
1.  Select the other inverter. 
CIRCUIT BREAKER TRIPPED 
 
1.  Nonessential circuit  Do not reset in flight. 
 
2.  Essential circuit    Reset  once.    If  it  trips again,
do not reset. 
BUS 
FEEDER 
CIRCUIT 
BREAKER
TRIPPED   (FUEL   PANEL   BUS   FEEDERS
AND   RIGHT   CIRCUIT   BREAKER   PANEL
BUS FEEDERS) 
 
1.  A short is indicated, do not reset in flight.