TM 1-1510-225-CL
N-4
*SECOND
ENGINE
START
(BATTERY
START)
1. First engine generator load 50% or less GEN
switch OFF.
2. Propeller area Clear.
3. Engine Start.
4. Engine and systems instruments Check.
5. BATTERY CHG annunciator Check.
6. INVERTER switch ON, check INVERTER lights
OFF.
7. Second engine GEN switch RESET, then ON.
8. CONDITION levers As required.
9. RED ANTICOLLISION light Reset.
ABORT START
1. CONDITION lever FUEL CUTOFF.
2. IGNITION AND ENGINE START switch
STARTER ONLY.
3. ITT Monitor for drop in temperature.
4. IGNITION AND ENGINE START switch OFF.
ENGINE CLEARING
1. CONDITION lever FUEL CUTOFF.
2. IGNITION AND ENGINE START switch OFF
(1 minute minimum).
3. IGNITION AND ENGINE START switch
STARTER
ONLY
(15
seconds
minimum,
40 seconds maximum).
4. IGNITION AND ENGINE START switch OFF.