TM 1-1510-225-CL
E-19
UNSCHEDULED ELECTRIC ELEVATOR TRIM
1. Control wheel disconnect switch Press fully.
O
2. Elevator trim switch OFF.
3. AP TRIM POWER circuit breaker Out.
ELECTROTHERMAL PROPELLER DEICE
(AUTO SYSTEM) MALFUNCTION
ZERO AMPS:
1. PROP deice switch Check AUTO.
IF AMPS REMAIN AT ZERO:
2. PROP deice switch OFF (for 30 seconds).
3. PROP deice switch AUTO.
IF AMPS REMAIN AT ZERO:
4. Manual
backup
system
Initiate. (See
electrothermal propeller Deice Manual System
Operation.)
BELOW 18 AMPS:
5. Operation Continue.
6. RPM Increase (briefly to aid in ice removal, if
propeller imbalance occurs).
OVER 24 AMPS
7. Monitor Continue operation if the PROP deice
circuit breaker switch does not trip.
8. RPM Increase (briefly to aid in ice removal, if
propeller imbalance occurs).
9. Loadmeter Monitor for excessive current drain.
If the PROP AUTO deice circuit breaker switch
trips, use the manual system.