TM 1-1510-225-10
3A-10
16. Cursor field value knob Select
AM or FM. Transmit frequency
(TX FREQ) page will appear.
17. # Key Press.
18. Keypad Enter frequency.
19. Enter knob Press.
20. Number 2 key Press to enter
transmit
frequency.
Transmit
Tone
(TX
TONE)
page
will
appear.
21. Cursor movement knob Place
cursor under last dot.
22. Cursor field value knob Set
desired value.
23. Number 2 key Press to select
transmit tone. Advanced features
page will appear.
24. Number 2 key Press if advanced
features are not required and
proceed to step 52.
25. Number 3 key Press if advanced
features are required. DISPLAY
FREQ page will appear.
NOTE
If NO is selected, asterisks (*) will appear
for the preset channel frequency during
operation.
26. Cursor value knob Turn to
display YES or NO.
27. Number 2 key Press to select
option. Receive only (RX ONLY)
page will appear.
28. Cursor value knob Turn to
display YES or NO.
29. Number 2 key Press to select
option. Receive type (RX TYPE)
page will appear.
30. Cursor value knob Turn to select
transceiver type.
NOTE
Only the RT-5000 transceiver is available.
31. Number 2 key Press to select
option. Receive Channel Discrete
(RX CMDS) page will appear.
NOTE
Channel discretes are a combination of five
electronic
switches
that
can
be
programmed to be activated with each
guard or main channel (transmit can be
different from receive). There are five
transmit and receive discretes assigned to
each transceiver. Outputs control external
interfaces such as antenna switching,
external encoder or decoder enable/disable
functions, or any external function or
equipment switching associated with a
given channel.
32. Cursor movement knob Place
cursor under appropriate space.
Switch #1 is in far right position
and switch #5 is in far left.
33. Cursor value knob Turn to select
value for each switch (1 = ground,
0 = open circuit).
34. Number 2 key Press to select
switch configuration. Transmit
Channel
Discrete
(TX
CMDS)
page will appear.
35. Cursor movement knob Place
cursor under appropriate space.
Switch #1 is in far right position
and switch #5 is in far left.
36. Cursor value knob Turn to select
value for each switch (1 = ground,
0 = open circuit).
37. Number 2 key Press to select
switch configuration. TX PWR
(transmit power) page will appear.
38. Cursor field value knob Turn to
select HI or LO.
39. Number 2 key Press to select
option.
Second
Intermediate
Frequency
Injection
(2ND
IF
INJECTION) page will appear.
NOTE
Intermediate Frequency (IF) injection is a
function that eliminates interfering signals
from the applicable IF range.