TM 1-1510-224-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
(a)
BATTERY CHARGE annunciator - Check
on. BATTERY CHARGE annunciator
should
extinguish
within
5
minutes
following a normal engine start on battery.
(b)
#1 and #2 INV annunciators - Check
extinguished. This procedure checks both
400 and 500 ampere current limiters that
tie the aircraft bus systems together.
12.
GENERATOR switch - RESET, then ON.
C1
NOTE
When voltage drops below approximately 20 volts,
the beacon light may become inoperative. To reset
beacon light, turn off for approximately 5 seconds,
then DAY or NIGHT.
13.
BEACON lights switch - Reset, then on.
ABORT START PROCEDURE
1.
CONDITION lever - FUEL CUTOFF.
2.
ENG START switch - STARTER ONLY.
3.
TGT -Monitor for drop in temperature.
4.
ENG START switch - OFF.
ENGINE CLEARING PROCEDURE
1.
CONDITION lever - FUEL CUTOFF.
2.
ENG START switch - OFF (15 minutes
minimum).
2-37