TM 1-1510-224-10
NOTE
The
EMERGENCY
lights
override
switch should be placed in the TEST
position and the emergency lights (5)
checked
for
illumination
and
intensity. A dim light indicates a
weak battery pack. At the completion
of the check, the switch must be
cycled from the TEST position to the
OFF/RESET position and then placed
in AUTO.
*14.
FUEL gages Check fuel quantity and gage
operation.
15.
HYD FLUID SENSOR TEST switch Check as
follows:
a.
HYD
FLUID
SENSOR
TEST
switch
Depress and hold. Check HYD FLUID
LOW annunciator light illuminates.
b.
HYD
FLUID
SENSOR
TEST
switch
Release. Check that annunciator light
extinguishes.
16.
Engine fire protection system Check as follows:
a.
ENG FIRE TEST switches Hold switches to
DET position, check that FIRE PULL
handle warning annunciators and MASTER
WARNING annunciators illuminate.
b.
ENG FIRE TEST switches Hold switches to
EXT position, check that SQUIB OK and
EXTGH DISCH annunciators and MASTER
CAUTION annunciators illuminate.
NOTE
If MASTER WARNING annunciators
are cancelled between tests, they
may not re-illuminate.
17.
Stall and gear warning system Check as follows:
a.
STALL WARN TEST switch TEST. Check
that warning horn sounds.
b.
LDG GEAR WARN TEST switch TEST.
Check that warning horn sounds and that
the LDG GEAR CONTR handle warning
lights illuminate.
18.
GPU Check connected and DC voltage if steps
19 through 26 are to be performed.
«19. Overhead control panel switches Set as required:
TM 1-1510-224-10
a.
Aircraft # 1 and # 2 INVERTER switches
ON.
b.
AUTO PLT POWER switch ON.
c.
AVIONICS MASTER POWER switch EXT
PWR.
d.
# 1 and # 2 EFIS POWER switches ON.
e.
ATT pushbutton selector switch (display
controller) Press as required.
f.
Autopilot EFIS 1/2 switch EFIS 1.
«20. Mission control panel switches Check and set as
required:
a.
Mission control panel circuit breakers -
Check in.
b.
ANT ORIDE switch AUTO ROTATE.
c.
MISSION CONTROL switch As required.
d.
RADIO ALT switch ON.
e.
ELINT/COMINT switches (2) As required.
f.
WOW OVERRIDE - OFF.
g.
BUS CROSS TIE switch As required.
h.
# 2 3-phase INV switch RESET/ON.
i.
# 1 3-phase INV switch RESET/ON.
j.
EXT PWR switches As required.
k.
AC phase meter switch As required.
i.
ASE SILENT switch OFF.
«21. INS - Align as required.
a.
Mode switch B (MFD) Depress to select
FPLN page.
b.
NAV SETUP (R5) Depress.
c.
INS SETUP (R5) Depress.
d.
INS mode selector STBY. Text at LI will be
blank until INS mode selector is placed in
STBY or ALIGN. The 1. LAST ALIGN
and 2. LAST KNOWN text will appear.
e.
Present position Enter by one of these
methods:
8-3