TM 1-1510-224-10
a.
Rotate TEST SEQUENCE switch
counterclockwise
to
SYS
NOT
RESET position. SYS NOT RESET
annunciator (amber) will illuminate.
DISPENSER
COMPLETE
annunciator
(green)
will
remain
illuminated.
b.
Reset FLARE counter to 30. ALL
FLARES EXPENDED shall not be
displayed.
Do
not
depress
MANUAL SYSTEM RESET switch.
NOTE
When the MANUAL SYSTEM RESET
switch is pressed and released, and
28 volts DC power is being applied,
the sequencer switch inside the
dispenser assembly resets, making
an audible sound as it rotates. If the
sequencer
switch
has
been
previously reset or if the switch is in
position 12 or 24, there will be no
such sound.
c.
Rotate TEST SEQUENCE switch
counterclockwise to STRAY VOLT
position.
STRAY
VOLTAGE
annunciator
(red)
should
not
illuminate.
d.
Rotate TEST SEQUENCE switch
counterclockwise to START/HOME
position.
NOTE
When the TEST SEQUENCE switch is
turned to the START/HOME position,
the
DISPENSER
COMPLETE
annunciator
will
extinguish,
the
STRAY VOLTAGE annunciator will
illuminate, and then will extinguish
when passing through the TS RESET
position.
8.
Remove M-91 test set from right fuselage
dispenser assembly.
c.
Chaff Dispenser (Right Nacelle) - Preliminary
Procedure.
1.
C-F selector switch on dispenser
C
(chaff).
2.
Set TEST SEQUENCE switch on test set
to START/HOME position.
3.
Clean dust, foreign particles, or moisture
from
breech
and
mounting
plate
of
dispenser.
4.
Connect M-91 test set to breech assembly
of
right
nacelle
dispenser
assembly.
Secure both mounting studs uniformly
tight using ball hexagonal key screwdriver
provided in test set carrying case.
5.
Obtain test set power cable from loose
tools and connect cable between exterior
connection
J1
(28V
DC)
on
aircraft
fuselage above trailing edge of wing and
aircraft power +28V DC (J1) of test set.
6.
Remove safety pins from right equipment
rack aft of copilot's seat, and on top skin
of right wing.
7.
Provide aircraft power to system by
resetting M-130 POWER circuit breaker.
8.
ASE mode select switch (multifunction
display, fig. 4-2) Depress to call up ASE
control page.
9.
L3 line selector switch Depress to set
DISPENSER to ARM.
10.
L4 line selector switch Depress to set
CHAFF to MAN.
11.
R5 line selector switch Depress to call up
ASE SETUP page.
12.
ASE/ACS keyboard unit (fig. 4-3) Key in
30 (30 will be displayed in scratchpad on
MFD), then depress line select switch R1
to set CHAFF COUNT to 30.
NOTE
When the test set is installed on the
dispenser assembly and 28 volts DC
aircraft power is being applied, the
sequence switch inside the dispenser
assembly resets, making an audible
sound as it rotates. There will be no
such sound if the sequencer switch
has been previously reset or if switch
is in position 12 or 24.
d.
Chaff Dispenser (Right Nacelle) System Test
Procedure.
1.
ASE mode selector switch Depress to
return to the ASE control page.
2.
Reinstall safety pins one at a time. PWR
FAIL shall appear below DISPENSER on
MFD.
3.
Remove
the
safety
pins
and
verify
DISPENSER is set to ARM on MFD.
4-7