TM 1-1510-223-10
NOTE
Replace any annunciator that does not
illuminate when pressed. If none of the
indicating annunciators illuminate, return
test
set
to
AVUM
(aviation
unit
maintenance).
b.
Rotate TEST SEQUENCE switch
clockwise to TS RESET position.
No visual indication will occur.
c.
Rotate TEST SEQUENCE switch
clockwise to SV SELF TEST
position.
STRAY
VOLTAGE
annunciator (red) will illuminate.
d.
Rotate TEST SEQUENCE switch
clockwise to next position, TS
RESET.
STRAY
VOLTAGE
annunciator (red) will extinguish
e.
Rotate TEST SEQUENCE switch
clockwise to next position, STRAY
VOLT.
STRAY
VOLTAGE
annunciator
(red)
should
not
illuminate.
f.
Rotate TEST SEQUENCE switch
clockwise to next position, SYS
NOT RESET. SYS NOT RESET
annunciator (amber) should not
illuminate.
If
annunciator
illuminates, press and release
MANUAL
SYSTEM
RESET
switch and SYS NOT RESET
annunciator
should
then
extinguish.
NOTE
When the MANUAL SYSTEM RESET switch is
pressed and released, and 28 volts DC power is
being applied, the sequencer switch inside the
dispenser assembly resets, making an audible
sound as it rotates. If the sequencer switch has
been previously reset or if the switch is in position
12 or 24, there will be no such sound.
g.
Rotate TEST SEQUENCE switch
clockwise to next position, DISP
COMPL.
h.
Press pilot's CHAFF DISPENSER
switch once. Press copilot's
CHAFF DISPENSER switch once.
On MFD, for each depression,
CHAFF
counter
should
count
down by an increment of one.
i.
On MFD, depress L3 line selector
switch until PRGM appears.
j.
Depress
pilot's
CHAFF
DISP
switch once. On MFD, number
shown on CHAFF counter should
decrease by one.
k.
On MFD, depress line select
switch L4 to set CHAFF to PRGM.
l.
Depress copilot's CHAFF DISP
switch once. On MFD, CHAFF
counter
will
read
29
minus
SALVO COUNT multiplied by
BURST COUNT as displayed on
ASE setup page.
m.
Repeatedly depress a CHAFF
DISP switch until CHAFF counter
reads
00
and
ALL
CHAFF
EXPENDED is displayed on MFD.
The
DISPENSE
COMPLETE
lamp (green) on test set shall be
illuminated.
NOTE
The DISPENSER COMP lamp may fail to
illuminate during the previous step due to
improper connection between the base plate
and breechplate. If this happens, remove
and reinstall base plate to ensure proper
connection and repeat CHAFF DISPENSE
tests. If this still does not result in proper
operation, verify the C-F selector switch is
in the C position.
5.
Perform the following operations on the
M-91 test set:
a
Rotate TEST SEQUENCE switch
counter-clockwise to SYS NOT
RESET position. SYS NOT
RESET annunciator (amber) will
illuminate.
b.
Press
and
release
MANUAL
SYSTEM RESET switch. SYS
NOT RESET annunciator (amber)
will extinguish and DISPENSE
COMPLETE LAMP will remain
illuminated.
c.
Reset the CHAFF counter to 30.
ALL CHAFF EXPENDED shall not
be displayed on MFD. Do not
depress
MANUAL
SYSTEM
RESET switch.
NOTE
When the MANUAL SYSTEM RESET
switch is pressed and released, and 28 volts
DC power is being applied, the sequencer
switch inside the dispenser assembly resets,
making an audible sound as it rotates. If the
sequencer switch has been previously reset
or if the switch is in position 12 or 24, there
will be no such sound.
d.
Rotate TEST SEQUENCE switch
counter-clockwise
to
STRAY
VOLT
position.
STRAY
VOLTAGE
annunciator
(red)
should not illuminate.
e.
Rotate TEST SEQUENCE switch
counter-clockwise
to
START/HOME position.
4-8