TM 1-1510-223-10
6.
Remove safety pins from on right
equipment rack aft of copilot's seat,
and on top skin of right wing.
7.
Provide aircraft power to M-130 system
by resetting the M-130 POWER circuit
breaker.
8.
ASE
mode
select
switch
on
multifunction display (MFD, fig. 4-2) -
Depress to call up ASE control page.
9.
L3 line selector switch - Depress to set
DISPENSER to ARM.
10.
R5 line selector switch - Depress to call
up ASE SETUP page.
b.
Flare Dispenser System Test Procedure.
1.
ASE mode selector switch - Depress to
return to ASE control page.
2.
Reinstall safety pins one at a time.
PWR
FAIL
shall
appear
below
DISPENSER on MFD.
3.
Remove
safety
pins
and
verify
DISPENSER is set to ARM on MFD.
NOTE
When the test set is installed on the
dispenser assembly and 28 volts DC aircraft
power has been applied, the sequencer
switch inside of dispenser assembly resets,
making an audible sound as it rotates.
There will be no such sound if the
sequencer switch has been previously reset
or if switch is in position 12 or 24.
On test set, TS PWR ON annunciator
(clear) illuminates and remains illuminated
throughout the test sequence until aircraft
power to test set (via test set power cable) is
disconnected or shut off.
4.
Perform the following operations on the
M-91 test set.
a.
Press to test remaining three
annunciators on test set Each
annunciator will illuminate.
NOTE
Replace any annunciator that does not
illuminate when pressed. If none of the
indicating annunciators illuminate, return
test
set
to
AVUM
(aviation
unit
maintenance).
b.
Rotate TEST SEQUENCE switch
clockwise to the TS RESET
position. No visual indication will
occur.
c.
Rotate TEST SEQUENCE switch
clockwise to SV SELF TEST
position.
STRAY
VOLTAGE
annunciator (red) will illuminate.
d.
Rotate TEST SEQUENCE switch
clockwise to TS RESET position.
STRAY VOLTAGE annunciator
(red) will extinguish.
e.
Rotate TEST SEQUENCE switch
clockwise
to
STRAY
VOLT
position.
STRAY
VOLTAGE
annunciator
(red)
should
not
illuminate.
f.
Rotate TEST SEQUENCE switch
clockwise to SYS NOT RESET
position. SYS NOT RESET
annunciator (amber) should not
illuminate.
If
annunciator
illuminates, press and release
MANUAL
SYSTEM
RESET
switch and SYS NOT RESET
annunciator should extinguish.
NOTE
When the MANUAL SYSTEM RESET
switch is pressed and released, and 28 volts
DC power has been applied, the sequencer
switch inside the dispenser assembly resets,
making an audible sound as it rotates. If the
sequencer switch has been previously reset
or if the switch is in position 12 or 24, there
will be no such sound.
g.
Rotate TEST SEQUENCE switch
clockwise to next position, DISP
COMP.
5.
Press either FLARE DISPENSE switch
once. For each depression the FLARE
counter on DCP should count down in
groups of three.
6.
On MFD, depress L5 repeatedly until
text reads RIPPLE FIRE ARMED.
Within 7 seconds , depress a FLARE
DISPENSE switch. Flare counter shall
count down to 00 and ALL FLARES
EXPENDED shall be displayed on
MFD. DISPENSE COMPLETE lamp
(green) on test set shall be illuminated.
NOTE
DISPENSER COMP lamp may fail to
illuminate during the previous step due to
improper connection between the base plate
and breech plate. If this happens, remove
and reinstall base plate to ensure proper
connection and repeat FLARE DISPENSE
tests. If this still does not result in proper
operation, verify the C-F selector switch is
in the F position.
7.
Perform the following operations on the
M-91 test set.
a.
Rotate TEST SEQUENCE switch
counter-clockwise to SYS NOT
RESET position.
4-6