TM 1-1510-218-CL
E-6
2. TGT and TORQUE Monitor (note readings).
3. BLEED AIR VALVE switch OFF.
4. Cabin pressurization Check.
EXCESSIVE DIFFERENTIAL PRESSURE
1. Cabin pressurization controller Select higher
setting.
IF CONDITION PERSISTS:
2. Oxygen (crew and passengers) As required.
3. LEFT BLEED AIR VALVE switch ENVIRO OFF
(light illuminated).
IF CONDITION STILL PERSISTS:
4. RIGHT BLEED AIR VALVE switch ENVIRO
OFF (light illuminated).
5. Descend As required.
IF CONDITION STILL PERSISTS:
6. Oxygen masks 100% and on.
7. CABIN PRESS switch DUMP.
8. BLEED AIR VALVE switches OPEN (if cabin
heating is required).
LOSS
OF
PRESSURIZATION
(ABOVE
10,000 FEET)
1. Crew oxygen masks 100% and on.
2. Passenger oxygen ON and checked to ensure
all passengers have oxygen masks on and are
receiving supplemental oxygen if required.