TM 1-1510-218-CL
E-5
DUCT
OVERTEMP
CAUTION
LIGHT
ILLUMINATED
1. CABIN AIR control In.
2. CABIN AIR/TEMP MODE switch AUTO.
3. CABIN AIR/TEMP switch Decrease.
4. VENT BLOWER switch HI.
5. CABIN AIR/TEMP MODE switch MAN COOL.
6. MANUAL TEMP switch DECREASE (hold).
7. LEFT BLEED AIR VALVE switch PNEU &
ENVIRO OFF.
8. Light still illuminated (30 seconds) LEFT BLEED
AIR VALVE switch OPEN.
9. RIGHT BLEED AIR VALVE switch PNEU &
ENVIRO OFF.
10. Light still illuminated (30 seconds) RIGHT BLEED
AIR VALVE switch OPEN.
ICE VANE FAILURE
1. Airspeed 160 KIAS or below.
2. ICE VANE CONTR circuit breaker Pull.
3. ICE VANE Operate manually.
4. Airspeed Resume normal airspeed.
ENGINE
BLEED
AIR
SYSTEM
MALFUNCTION
BLEED AIR FAILURE LIGHT ILLUMINATED
1. BRAKE DEICE switch Off.