TM 55-6670-200-14&P
(3) Press CELL BALANCE switch (1) and
adjust WEIGHT knob (8) until meter pointer is on
zero. If a small plus reading is obtained, divide
value by 2 and subtract from total weight reading
for that cell. If there is a small minus reading, add
amount indicated on zero shift scale to reading
obtained for that cell. If there is an appreciable
difference (greater than 25 pounds), repeat entire
weighing procedure.