TM 55-4920-401-13&P
Table 4-3. Spread Circuit Check Table.
Spread Switch
Jumper
Position
Position
All
A-B, A-C, A-D,
A-E, A-F, A-G,
A-I-I, A-I
1
A-B
2
A-C
3
A-D
4
A-E
5
A-F
6
A-G
7
A-H
8
A-I
RX1000. Remove resistor and short alligator clips.
Meter shall read zero.
(8) Connect 1 100K (+ 5%) resistor between
the alligator clips. Meter shall read 100K (+ 10%).
g. Resistance Check Circuit Accuracy Check.
(1) Connect BH485 instrument cable to
INSTRUMENT CABLE receptacle and connect
resistance check adapter to instrument cable.
(2) Turn RESISTANCE and A/C INDICATOR
CHECK switch to NULL BAL position and turn
FUNCTION SELECT switch to RES.
(3) Adjust screw on RESISTANCE & A/C
INDICATOR CHECK meter until meter reads zero.
(4) Connect a precision 22-ohm resistor (table
1-15) to terminals of resistance check adapter.
(5) Turn RESISTANCE & A/C INDICATOR
CHECK switch to 22 . RESISTANCE & A/C
INDICATOR check meter shall read zero.
(6) Replace 22-ohm resistor of step (4) with a
precision 15-ohrn resistor and turn RESISTANCE&
A/C INDICATOR CHECK switch to 15 . Meter
shall read zero.
(7) Replace 15-ohm resistor of step (6) with a
precision 8-ohm resistor and turn RESISTANCE &
A/C INDICATOR CHECK switch to 8 . Meter shall
read zero.
(8) Replace 8-ohm resistor of step (7) with a
precision 4.21 ohm resistor and turn RESISTANCE
& A/C indicator check switch to 4.21 . Meter shall
read zero.
h . F u n c t i o n a l a n d A c c u r a c y C h e c k of
Aircraft Indicator Check Circuit.
(1) Connect BH485 instrument cable to
INSTRUMENT CABLE receptacle and connect
BH822 egt indicator check adapter to instrument
cable.
(2) Turn FUNCTION SELECT switch to A/C
I N D C H K p o s i t i o n,
R E S I S T A N C E & A / C
INDICATOR CHECK switch to NULL BAL
p o s i t i o n,
a n d T E M P E R A T U R E s w i t c h to
OPERATE position.
(3) Connect a digital multimeter (table 1-15)
with a 100 mdvc range between the + and - eyelet of
the egt indicator check adapter if the adapter is for
DArsonval type indicators or between terminal A
(+) and terminal B (-) if the adapter is for null-
balance type indicators.
(4) Turn A/C IND ADJ potentiometer from
counterclockwise end to clockwise end while
observing multimeter. Range of potentiometer shall
be approximately 0-65 mvdc and there shall be no
open spots throughout the range. During this check,
T E M P º C i n d i c a t o r s h a l l f o l l o w s e t t i n g o f
potentiometer and display readings throughout the
range of ambient temperature to 1399° C.
NOTE
4.21 position of RESISTANCE & A/
C INDICATOR CHECK switch is for
checking aircraft circuit resistance
only.
4-5