TM 55-1510-222-10
(b) LIGHT. Enables monitoring REPLY
indicator for mode 4 operation.
(c) OUT. Deactivates monitor mode.
(12)
MODE 3/A code selectors. Select
desired reply codes for mode 3/A operation.
(13)
MODE 2 code selectors. Select desired
reply codes for mode 2 operation. The cover over mode
select switches must be slid forward to display the
selected mode 2 code.
(14)
MODE 1 code selectors. Select desired
reply codes for mode 1 operation.
(15) MODE 4 TEST-ON-OUT switch. Selects
test mode of Mode 4 operation.
(a) TEST. Activates built-in-test of mode 4
operation.
(b) ON. Activates mode 4 operation.
(c) OUT. Disables mode 4 operation.
(16)
MODE 4 code control. Selects preset
mode 4 code.
(17) M-C, M-3A, M-2, and M-1 switches. Select
test or reply mode of respective codes.
(a) TEST. Activates self-test of selected
code. Transponder can also reply.
(b) ON. Activates normal operation.
(c) OUT. Deactivates operation of
selected code.
(18)
POS
IDENT
pushbutton.
When
pressed, activates transponder identification reply.
c.
Transponder - Normal Operation.
(1) Turn-on procedure: MASTER switch -
STBY. Depending on the type of receiver installed, the
TEST/MON NO GO indicator may illuminate. Disregard
this signal.
(2) Test procedure:
NOTE
Make no checks with the master
switch in EMER, or with M-3/A codes
7600 or 7700 without first obtaining
authorization from the interrogating
station(s).
1.
Allow set two minutes to warm up.
2.
Select codes assigned for use in modes 1 and
3/A by depressing and releasing the pushbutton
for each switch until the desired number
appears in the proper window.
3.
Lamp indicators - Operate press-to-test feature.
4.
M-1 switch - Hold in TEST. Observe that no
annunciators illuminate.
5.
M-1 switch - Return to ON.
6.
Repeat steps 4 and 5 for the M-2, M-3/A and M-
C mode switches.
7.
MASTER control - NORM.
8.
MODE 4 code control - A. Set a code in the
external computer.
9.
MODE 4 AUDIO OUT switch - OUT.
(3) Modes 1, 2, 3/A, and/or 4 operating
procedure:
NOTE
If the external security computer is
not installed, a NO GO annunciator
will illuminate any time the Mode 4
switch is moved out of the OFF
position.
1.
MASTER control - NORM.
2.
M-1, M-2, M-3/A, and/or MODE 4 ON-OUT
switches - ON. actuate only those switches
corresponding to the required codes. The
remaining switches should be left in the OUT
position.
3.
MODE 1 code selectors - Set (if applicable).
4.
MODE 3/A code selectors - Set (if applicable).
5.
MODE 4 code control - Set (if required).
6.
MODE
4
REPLY
indicator
-
Monitor
to
determine when transponder set is replying to a SIF
interrogation.
7.
MODE 4 AUDIO OUT switch - Set (as required
to monitor Mode 4 interrogations and replies).
8.
MODE 4 audio and/or indicator - Listen
3-79